FIG. 3-1 AFC1200 System Block Diagram
3.1.1 System Block Diagram Description
wThe System construction provides control for up to 24 spindles through the use of a single
ISA Main Controller Unit.
wCommunication between the ISA Main Controller Unit and up to 24 Axis Controller Units is
accomplished via a communication bus ribbon cable (MA/AA cable).
wTool assemblies connect to their respective Axis Controller Units via a set of three homerun
cables: Motor, Encoder, and Sensor / Preamp (Transducer) cables.
wA color VGA CRT (or optional LCD) and keypad provide the interface required to monitor
and adjust System operations.
3.1 System Block Diagram
Chapter 3: System Description
Chapter 4: Individual Part Names.
Page 3-1
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - 

FIG. 3-1 AFC1200 System Block Diagram3.1.1 System Block Diagram DescriptionwThe System construction provides control for up to 24 spindles th

Page 2

The information displayed in DSP 1 and DSP 2 on the Axis Unit is determined by the ISAMain Controller Unit's AXIS-DSP switch setting. Th

Page 3

3.2.5 Nutrunner (Tool)FIG. 3-2-5 Nutrunner (Tool)wENCODERP Environmentally isolated angle encoder.P Provides feedback to Servo Amplifier. P P

Page 4

3.2.6 PRBU-DFT Unit (Preamplifier Cable Extender)P This unit can extend the preamplifier cable of the DFT tool up to 100 feet.P The maximum le

Page 5

Chapter 3: System DescriptionPage 3-13PRBU-DFTMAX. 50 FEETMAX. 50 FEETAFC1200 ENCLOSUREPOWERHEAD

Page 6

wDiscrete 24 VDC true low I/O on both the ISA Main Controller Unit and the Axis ControllerUnit provide direct communication with the PLC, as w

Page 7

3.2 Component Description3.2.1 KEYPAD (K/B)The keypad provided for the AFC1200 System is used for data entry as related to System setup andope

Page 8

3.2.2 Monitor (VGA CRT)FEC INC. provides a color VGA monitor (CRT) as part of the System standard configuration.The monitor serves to display

Page 9

3.2.3 ISA Main Controller UnitThe ISA Main Unit controls communication between the Axis Units and the user interface. Reference Figure 3-1 for

Page 10

(NOT USED)24(NOT USED)23DSUB 15-pin female VGA CRT (monitor) connector. May be used toconnect an optional LCD Display.CRT22DSUB 9-pin male in

Page 11

Connector for communication bus ribbon cable to Axis Unit.MULTI26DSUB 9-pin female communication connector. (Option)RS42225DESCRIPTION (REFE

Page 12

3.2.4 AXIS CONTROLler UNIT (Servo Amplifier)FIG. 3-2-4 Axis Controller UnitThe following table describes the components and features of the

Page 13

200~230 VAC, 50/60 Hz, 3-phase input power connector.AC-POWER 18Six (6) dual-color LED indicators. Refer to Axis Unit Reject Display Tableon